Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9685281

- Product Categories
- Friendly Links
Information Name: | EAST dual conductor heating cables supply power to warm A/1R 1750/18 type |
Published: | 2013-08-05 |
Validity: | 30 |
Specifications: | |
Quantity: | 100000.00 |
Price Description: | |
Detailed Product Description: | EAST dual heating cable power to warm A/1R 1750/18 type Guizhou Yi New Technology Development Co., Ltd., located in Guiyang National High-tech Development Zone, with a total investment of 16 million yuan, is the only professional "single, dual temperature heating cable guide, R & D, production and sales of high-tech enterprises. EAST EASTFIRE company since the late 1990s, the first to introduce the Nordic electricity to warm the production and application of technology, ushering in the Chinese heating cables electric floor heating history. After years of sharpening, EAST EASTFIRE advanced technology company in the Nordic references on the basis of its own research and development, production to meet the Chinese market, the environment can be adapted to a variety of heating independent intellectual property products, "the fourth generation of fully shielded metal High temperature heating cable. "12 years of product development, production and sales experience in the heating cable has to become China EAST EST heating cable power to warm the brand synonymous with the company's product development capabilities topped the domestic industry first in sales record highs. Nowadays, EAST EASTFIRE company employs more than 90, and the formation of a vibrant high-tech R & D team, established a perfect, scientific research and development system efficient production company owns the only professional production of heating cables multi-channel high-voltage lines and detection methods, unique technology leader in the same industry. Our products have passed the ISO9001 quality system certification, and many other relevant institutions, products strictly in accordance with the IEC60800 international standards of production and by the official EU CE certification and the quality of supervision through national wire and cable Inspection Center. EAST EASTFIRE company is also committed to energy saving heating cable applications and fields of intelligent control system development, system application is also the domestic industry leader. EAST EST intelligent building heating systems, is the mature electric heating cable heating to warm the large-scale intelligent building control system, which has been widely used in homes, villas, apartments, schools, hospitals, office buildings and other buildings, while in agriculture, industry and other fields of application is very extensive. EAST EST with " Today's quality is tomorrow's market "as a corporate policy, and strictly control product quality. adhering to the" honesty, technology first, service first "business philosophy, to provide all users with first-class products, first-class service. now, EAST Iraq Rest of the warmth from the Chinese brought to the world. EAST EASTFIRE temperature single-conductor heating cables Intro: high-temperature heating cable structure: 1, core: core wire having a positive temperature coefficient of resistance of the metal alloy wire components, linear rated power of 18w / m. 2, Insulation: EASTFIRE heat insulation heating cable with double insulation structure, the insulating layer directly affects the quality of life of the heating cable, heating cable insulation temperature EST layer through trial and error, at 140 ℃ high temperature high temperature layer deformation, not shrinking. 3, grounding wire: ground wire from the 8 diameter of 0.4mm tinned copper lines. 8 tinned copper wire area 1.0048m square meters, in line with the provisions of the International Electrotechnical Commission IEC800 grounding provisions shall not be less than 1m square. 4, metal shielding layer: In the process of using the heating cable, since the current role will be formed around the heating cable electromagnetic field, electromagnetic field than if 100 micro Tesla will be on human health and other electrical impact through the effective protection of the metal shield, the electromagnetic field within the core control line, so they can not spread out, then the ground wire to the electromagnetic field into the earth, so that the heating cable and the earth formation potential. tested EASTFIRE electric floor heating electric field strength generated value is within the scope of national security, 1/1000 (state of the electric field strength is 4000 volts / m, EST heating cable is 4 volts measured data / m); magnetic induction intensity values ??of up to 13%, the lowest 6% (state of the magnetic flux density is 100 Witte Tesla, EASTFIRE electricity to warm up to 13 measured data Witt Tesla, Tesla minimum 6 Witt). much below the national standard, higher than the national safety regulations, harmless, can be assured. 5, the outer sheath: PVC outer sheath for high-quality material. PVC has good anti-corrosion, anti-acid, anti-aging effects, and 100% waterproof. temperature heating cables related technical data 1, heating cable diameter: According to the State Administration of Quality Supervision, Inspection and Quarantine and the Standardization Administration of China in 2007 published "GB/T20841-2007IEC 60800:1992 rated voltage 300/500V comfort heating and prevention of ice heating cables "provides heating cable diameter not less than 6mm, EASTFIRE heating cable has a diameter of 6.5 ± 0.3mm, higher than the national standard. 2, heating cables linear power ─ 18W / m 3, the implicit connection: "EST" heating cable in the cold line hotline connection with the use of a proprietary patented welding methods currently on the market most of the production of heating cable with cold connection method (cold, hot Mechanical crimping manner) in the long run, the heating part and the cold part of the contact point will lead to poor contact due to the formation of large resistance, high temperature part of the joint, the joint eventually burn out. cold terminal like a home furnace used as electric wire is rarely blown, and electric wire and power connectors often problematic. while the "EST" implicit heating cable connector (a small-diameter wire butt method) patented welding method is to heat the cold lead wire for the integrated solution to solve the alternating hot and cold brought expansion and poor contact, to ensure that the heating cable cold leads, hot wire welding smooth transition, so that the heating cable in one go without stay flaws; heating cable used to ensure the reliability, security, waterproof and resistant to mechanical external damage. ensure the service life of the heating cable. 4, heating cables logo: According to the State Administration of Quality Supervision, Inspection and Quarantine and the Standardization Administration of China in 2007 was released "GB/T20841 ─ 2007/IEC 60800:1992 rated voltage 300/500V comfort heating and prevention of ice Heating cables" provides heating cable surface markers legible, easily identifiable, rub resistance, signs spacing greater than 500mm, the most Importantly, "EST" cold joints in the heating cable with a way to accurately identify the marking on the cable in the heat, to warm the construction and testing to bring great convenience. EASTFIRE national technical indicators and temperature high-temperature technology: State Quality Supervision, Inspection and Quarantine and the Standardization Administration of China in 2007 released "GB/T20841-2007/IEC 60800:1992 rated voltage 300/500V comfort heating and prevention of ice Heating cables" provisions; heating cable core wire heating temperature up to 90 ℃, cable PVC jacket up to 65 ℃. while EASTFIRE high temperature heating cable core wire heating temperature up to 100 ℃, PVC sheath can withstand temperatures up to 90 ℃. Ian Special high-temperature heating cables indicators are far higher than the national standard, and its meaning is: made with ordinary electric heating cable to warm above can not be used in its thick carpet or other floor coverings thereof as otherwise scattered out due to higher temperatures heating cables can cause malfunction, resulting in heating cable is not heating, and high-temperature heating cable EASTFIRE there is no such risk, EST's destructive test data are as follows: core wire 140 ℃, the temperature of the carpet 100 ℃, the carpet surface temperature of 48 ℃. carpet thickness is 10mm, test time 180 days * 24 hours non-stop, high temperature heating cable continues to work, while a control under the same conditions with a thick mulch of ordinary heating cable in the power 11 days has been damaged, no heating! EAST EASTFIRE company is also committed to energy saving heating cable applications and fields of intelligent control system development, system application is also the domestic industry leader. EAST EST intelligent buildings heating system is mature domestic electrical heating cable heating to warm the large-scale intelligent building control system, which has been widely used in homes, villas, apartments, schools, hospitals, office buildings and other buildings, while in agriculture, industry and other fields of application is very extensive . EAST EASTFIRE to "Today's quality is tomorrow's market" as a corporate policy, and strictly control product quality. adhering to the "honesty, technology first, service first" business philosophy, to provide all users with first-class products, first-class The service now, EAST EASTFIRE the warmth from China to the world. |
Admin>>>
You are the 16126 visitor
Copyright © GuangDong ICP No. 10089450, Guizhou Yi New Technology Development Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 16126 visitor
Copyright © GuangDong ICP No. 10089450, Guizhou Yi New Technology Development Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility