Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9685281

- Product Categories
- Friendly Links
Information Name: | Supply Guang'an intelligent electric floor heating | heating cables Guang'an |
Published: | 2013-08-12 |
Validity: | 30 |
Specifications: | |
Quantity: | 100000.00 |
Price Description: | |
Detailed Product Description: | Guang'an intelligent supply electricity to warm | Guang'an EAST EST heating cable heating cable temperature Shan Intro: high-temperature heating cable structure: 1, core: core wire having a positive temperature coefficient of resistance of the metal alloy wire composed of linear power rating of 18w / m. 2, the insulating layer: EASTFIRE heat insulation heating cable with double insulation structure, the insulating layer directly affects the quality of life of the heating cable, heating cable insulation temperature EST through trial and error, at 140 ℃ high temperature high temperature layer deformation, not shrinking. 3, grounding wire: ground wire from the 8 diameter of 0.4mm tinned copper lines. 8 tinned copper wire area of ??1.0048m square meters, in line with the provisions of the International Electrotechnical Commission IEC800 line shall not be less than 1m square grounding requirements. 4, a metal shield layer: in the course of the heating cable, since the current role in the electromagnetic field is formed around the heating cable, if more than 100 micro Tesla fields will be on human health and other electrical impact. Through the effective protection of the metal shield, the electromagnetic field within the core control line, so they can not spread out, and then by the electromagnetic field into the earth ground wire to make the heating cable and the earth formation potential. Through testing, EASTFIRE electric floor heating electric field strength generated value is within the scope of national security, 1/1000 (state of the electric field strength is 4000 volts / m, measured data EASTFIRE heating cable is 4 volts / m); magnetic induction the highest value was 13%, the lowest 6% (state of the magnetic induction intensity is 100 Witte Tesla, EASTFIRE electricity to warm up to 13 measured data Witt Tesla, Tesla minimum 6 Witt). Far below the national standard, higher than the national safety regulations, harmless, can be assured. 5, the outer sheath: PVC outer sheath for high-quality material. PVC has good anti-corrosion, anti-acid, anti-aging effects, and 100% waterproof. High-temperature heating cables related technical data 1, heating cable diameter: According to the State Administration of Quality Supervision, Inspection and Quarantine and the Standardization Administration of China in 2007 published "GB/T20841-2007IEC 60800:1992 rated voltage 300/500V living comfort heating and prevention Heating cables with icing "provides heating cable diameter not less than 6mm, EASTFIRE heating cable has a diameter of 6.5 ± 0.3mm, higher than the national standard. 2, heating cables linear power ─ 18W / m 3, the implicit connection: "EST" heating cable in the cold line hotline connection with the use of a proprietary patented welding method. Currently on the market most of the production of heating cable with cold connection method (cold, hot with mechanical crimping manner). In the long run, the heating part and the cold part of the contact point will lead to poor contact due to the formation of large resistance, high temperature part of the joint, the joint eventually burn out. Cold joints like a home furnace used as electric wire is rarely blown, and electric wire and power connectors often a problem. The "EST" implicit heating cable connector (a small-diameter wire docking method) method is patented heating wire welding with cold leads as one solution to solve the alternating hot and cold brought expansion and poor contact , to ensure that the heating cable cold leads, hot wire welding smooth transition, so that the heating cable at one go, leaving no blemishes; heating cables can be used to ensure the reliability, security, waterproof and resistant to mechanical external damage. Ensure that the service life of the heating cable. 4, heating cables logo: According to the State Administration of Quality Supervision, Inspection and Quarantine and the Standardization Administration of China in 2007 published "GB/T20841 ─ 2007/IEC 60800:1992 rated voltage 300/500V comfort heating and prevention of ice Heating cables" heating cables required surface markers legible, easily identifiable, rub resistance, signs spacing greater than 500mm, the most important is that the "EST" heating cable in cold joints, accurate way to identify with the marking on the cable in the heating, to warm the construction and testing to bring great convenience. National technical specifications and high-temperature high-temperature technology EASTFIRE: State Quality Supervision, Inspection and Quarantine and the Standardization Administration of China in 2007 published "GB/T20841-2007/IEC 60800:1992 rated voltage 300/500V comfort heating and Heating cables with anti-icing "provisions; heating cable core wire heating temperature up to 90 ℃, cable PVC jacket up to 65 ℃. And EASTFIRE temperature heating cable core wire heating temperature up to 100 ℃, PVC sheathed maximum temperature can be resistant to 90 ℃. EASTFIRE high temperature heating cables indicators are far higher than the national standard, and its meaning is: made with ordinary electric heating cable to warm above can not be used in its thick carpet or other floor coverings thereof as otherwise scattered due to temperature rise heating cable does not come out will cause malfunction, resulting in heating cable is not heating, and high-temperature heating cable EASTFIRE there is no such risk, EST's destructive test data are as follows: core wire 140 ℃, the carpet temperature of 100 ℃, carpet surface temperature 48 ℃. Carpet thickness is 10mm, test time 180 days * 24 hours non-stop, high temperature heating cable continues to work, while a control under the same conditions with a thick mulch of ordinary heating cable 11 days after the power has been damaged, the system is no longer Hot! EAST EASTFIRE company is also committed to energy saving heating cable applications and fields of intelligent control system development, system application is also the domestic industry leader. EAST EASTFIRE intelligent building heating system is mature domestic electrical heating cable heating to warm the large-scale intelligent building control systems. It has been widely used in homes, villas, apartments, schools, hospitals, office buildings and other buildings, while in agriculture, industry and other fields of application is also very extensive. EAST EASTFIRE to "Today's quality is tomorrow's market" as a corporate policy, and strictly control product quality. Adhering to the "honesty, technology first, service first" business philosophy, to provide all users with first-class products, first-class service. Now, EAST EASTFIRE the warmth from China to the world. Electric floor heating health tips in fact, some of the low temperature, but more favorable to health. Studies have shown that short life of people in tropical regions, and boreal regions of the human life span is relatively longer. Winter indoor temperature controlled at 23-26 degrees Celsius, and as close to the lower limit is more appropriate. Therefore recommended that each family can buy a thermometer, easy to control the indoor temperature. In addition, a winter, a lot of people at home are closed windows, air conditioning came in fear, dissipate heat, reduce the indoor temperature. The central heating temperature can not be self-regulating, indoor air circulation, will reduce the body resistance. Recommended to ventilate the room every day to ensure the indoor air fresh, the best ventilation time is 10 o'clock in the afternoon between three or four points. Morning air pollution is more serious, is not recommended to open the windows. There is no ventilation when they observed haze, if visibility is low, do not open the window on the first, so as not to cause indoor pollution. For good ventilation is recommended when fitting installed on the edge of the windows can be opened. Such windows can be avoided when the cold wind blowing on people, reduce colds, but also to prevent rain and snow into the house. If the family room more, you can ventilate the room one by one, to ensure that the overall room temperature. Finally, you need to be reminded that South transparent house ventilation is better, less effective high-rise buildings, ventilation should be relatively extended time |
Admin>>>
You are the 16126 visitor
Copyright © GuangDong ICP No. 10089450, Guizhou Yi New Technology Development Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 16126 visitor
Copyright © GuangDong ICP No. 10089450, Guizhou Yi New Technology Development Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility